Original Article

The Effect of Glass Ceramic Layering on the Marginal Leakage of Zirconia Supported Crowns

10.14235/bas.galenos.2023.26818

  • Bahar ELTER
  • Gamze PAKEN
  • M. Erhan ÇÖMLEKOĞLU

Received Date: 31.12.2022 Accepted Date: 27.11.2023 Bezmialem Science 2024;12(2):149-154

Objective:

The purpose of this study was to evaluate the effect of veneering with lithium-disilicate glass-ceramic material on the marginal microleakage of zirconia-supported crowns.

Methods:

Ten freshly extracted human third molars were embedded in an acrylic mold from the roots. Crown preparation of each tooth half was handled differently. The distal half of each tooth was prepared with a chamfer-type margin (1.2 mm), while the mesial half was finished with a mini-chamfer (0.6 mm). Zirconia frameworks were designed and manufactured with computer-aided design/computer-aided manufacturing, and the frameworks were veneered on the distal surfaces of the framework using lithium-disilicate glass-ceramic. Specimens were thermocycled and immersed in a basic fuchsine dye solution for 24 hours. Four cross-sections were made from each specimen (n=40), and dye penetrations were recorded under a stereo microscope for microleakage measurements. The microleakage values were statistically analyzed with a Mann-Whitney U test (α=0.05).

Results:

Mean microleakage values were recorded for each group. The values for the ceramic veneered margin group were noted as 1.17±0.69 mm, while the values for the zirconia margin group were noted as 1.03±0.74 mm. The results did not show significant differences for the compared groups (p=0.102).

Conclusion:

Lithium-disilicate glass-ceramic veneering for zirconia-supported restorations did not enhance the marginal seal capability.

Keywords: Finish-line, glass-ceramic, marginal microleakage, zirconia

Introduction

In recent years, the increasing demand of patients for high esthetic restorations has contributed to the development of new restorative materials that aim to ensure the longevity of the restoration by improving its mechanical and optical properties and minimizing technical problems. Zirconia has many beneficial properties, such as excellent biocompatibility, high strength, and low plaque accumulation. The material also has low translucency owing to its crystalline microstructure. High-strength zirconia is usually used as a framework and should be layered with veneering ceramic to meet patients’ esthetic expectations (1-3). With computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it is possible to fabricate the optimal zirconia coping/framework for crown and bridge restorations. Despite its high costs CAD/CAM ensures reproducible results by reducing the technician errors that occur in the laboratory and providing standardization (4). After manufacturing the zirconia framework, glass-ceramics can be applied through several manufacturing processes, including the layering and press techniques (5,6). In the layering technique, ceramic powder is applied directly to the zirconia core before firing. In the press technique, a ceramic ingot is heated and forced under pressure after lost wax technique application (7).

In addition to the material’s esthetic properties, strength, and biocompatibility, precise marginal fit and marginal seal are also fundamental requirements for the clinical success of dental restorations (1). The marginal finish lines of full-crown restorations can be classified as feather-edged, shoulder, mini chamfer, and chamfer (8). Studies have shown that finish line type, ceramic veneering procedures, differences in the thermal expansion coefficients between the core and the veneering ceramic, and veneering ceramic thickness affect the marginal adaptation of the restorations (9-12). An inadequate marginal adaptation can result in a gap between the restoration and the prepared tooth, thus accelerating the dissolution of the cement. Subsequently, oral bacteria and food debris accumulate in this space, leading to secondary caries, pulpal lesions, postoperative sensitivity, periodontal disease, and marginal discoloration (8,13-15). Also, the cementation process affects the marginal adaptation and, subsequently, the marginal microleakage of the restoration (12). The microleakage amount of a cemented restoration depends on many other factors, like tooth preparation, restoration material, restoration fabrication method, cement type, and cementation procedures (16,17).

In the literature, the effects of different manufacturing methods (18), various cement types (19), and finish line designs (20) on marginal microleakage of zirconia frameworks have been investigated. To the authors’ best knowledge, there is limited study on the effect of the finish line material on the microleakage amount of zirconia-supported crown restorations. The zirconia-supported restorations mainly have zirconia finish lines. However, due to the absence of glass phase or silica in their structure, they do not show sufficient adhesion ability to the tooth as much as glass-ceramic (1). The surface roughening process, which is applied to glass-ceramics, such as hydrofluoric acid, before cementation, is not effective for zirconia due to its high volume of crystals and absence of glass matrix. It is easy to achieve strong, predictable adhesive retentions on silica-based ceramics, but zirconia has limitations in bonding with dental tissue due to its composition (21,22).

Finishing the margin area with lithium-silicate glass-ceramic material was thought to contribute to a better marginal seal and lower marginal microleakage with the help of increased adhesion to the tooth structure. Therefore, the purpose of this study was to evaluate the influence of veneering with lithium-disilicate glass-ceramic on the marginal microleakage of zirconia-supported crowns using optical image processing software.

The null hypothesis was that there would be no difference in marginal microleakage values between the two finish lines prepared with zirconia and lithium-disilicate glass-ceramic veneered zirconia.


Methods

This study was approved by the İstanbul Okan University Clinical Research Ethics Committee (approval number: 56665618-204.01.07, date: 22.07.2020).

Ten freshly extracted and cleaned third human molars were embedded in an acrylic mold (Figure 1a). The distal half of each tooth was prepared with a chamfer margin (1.2 mm), while the mesial half was finished with a mini-chamfer (0.6 mm)
(Figure 1b). The preparations were carried out by the same researcher, and a new diamond bur (Brasseler, Savannah, GA, USA) was used under water cooling. The prepared teeth were then scanned with an intra-oral digital scanner (CEREC Omnicam, Dentsply Sirona, Bensheim, Germany). The crown frameworks were designed using computer-aided design software (CEREC 4.3, Dentsply Sirona) (Figure 1c). Margin lines were drawn, leaving a homogenous margin thickness of 0.6 mm in the zirconia margin halves. On the other half side, an additional space of 0.6 mm was left for veneering ceramic material in the ceramic veneered margin group. Partially sintered zirconia blocks (inCoris Z.I., Dentsply Sirona, Bensheim, Germany) were milled (CEREC inLab MC XL, Dentsply Sirona, Bensheim, Germany) for the fabrication of the frameworks (Figure 2). The milled frameworks were then sintered with a sintering furnace (inFire HTC speed, Dentsply Sirona, Bensheim, Germany) according to the manufacturer’s instructions.

Following the sinterization period, the zirconia frameworks were cooled down carefully. Each zirconia framework was fitted on the corresponding prepared tooth and checked for optimal adaptation. The frameworks were veneered on the distal surfaces of the zirconia framework using a lithium-disilicate glass-ceramic (IPS e.max Ceram, Ivoclar Vivadent, Schaan, Liechtenstein), which had a convenient coefficient of thermal expansion in terms of zirconia (Figure 2). The ceramic veneering process was completed in two firings using a ceramic furnace (Vita Vacumat 6000 M, Vita Zahnfabrik, Baden-Wurttemberg, Germany).

The prepared crowns were cemented using a dual-curing resin cement (Multilink N, Ivoclar Vivadent, Schaan, Liechtenstein). Following cementation, ten specimens were subjected to 5.000 cycles of thermal cycling between 5 °C and 55 °C with a dwelling time of 20 seconds (23). Then, the specimens were immersed in a basic fuchsine dye solution for 24 hours. After the specimens were removed from the solution, residual surface stains were cleaned with a toothbrush under running water. Four cross-sections were taken from each restoration-tooth complex for the microleakage measurements (n=40). A total of 80 measurements of dye penetration were recorded under a stereo microscope at a magnification of 20 (Leica Microsystems, Germany). Each microleakage value was defined and recorded as the distance of the stain penetrated from the outer border of each margin using optical image processing software. The recordings were then converted to a millimetric scale. Both zirconia and ceramic veneered zirconia halves of restorations were measured to compare the results.

Statistical Analysis

Statistical analysis was performed using SPSS 18.0 (SPSS, Chicago, USA) for Windows.


Results

The Shapiro-Wilk test was used to examine whether the data showed normal distribution. The microleakage values were analyzed with Mann-Whitney U test since the data did not show normal distribution. P-values less than 0.05 were considered statistically significant. Mean microleakage values were evaluated and the values for ceramic veneered margin group was 1.17±0.69 mm, (Figure 3a) while the values for non-veneered zirconia margin group was 1.03±0.74 mm (Table 1, Figure 3b). There were not significant differences between the two margin groups (p=0.102).


Discussion

The null hypothesis was accepted because veneering of zirconia frameworks with lithium-disilicate glass-ceramic did not cause a difference in marginal microleakage values.

Studies have investigated the effect of veneering ceramics in zirconia framework on marginal, internal, and horizontal discrepancies (24-26). However, not enough study was found on the effect of finish line material on microleakage after cementation. Pak et al. (27) evaluated the marginal fit of two different zirconia based crown systems (Digident CAD/CAM, Lava CAD/CAM) before and after ceramic veneering. The ceramic veneering process was found to have increased the marginal gaps between the teeth and the restorations for both groups (Digident increased from 61.52 to 83.15 µm; Lava increased from 62.22 to 82.03 µm). Kohorst et al. (26) also evaluated the marginal fit of two different, four-unit zirconia (VITA In-Ceram YZ Cubes, KaVo Everest ZS Blanks) frameworks after veneering with recommended ceramic systems. While frameworks from Everest ZS Blanks veneered with GC Initial Zr ceramic showed decreased marginal gap (p=0.019) and internal gap (p=0.001); frameworks from In-Ceram YZ Cubes veneered with VITA VM9 ceramic showed no differences after the veneering process. It was concluded that, extend of distortions after the veneering process depended on the type of zirconia and ceramic combination. Vigolo and Fonzi (28) evaluated the marginal fit of three different ceramic veneered zirconia systems (Everest veneered with Vita D-ceramic, Procera veneered with NobelRondo Zirconia, Lava veneered with Lava Ceram). The measurements were handled before ceramic application, after ceramic firing and after glaze firing. It was reported that ceramic firing cycles and glaze cycles did not alter the marginal fit of zirconia based ceramic restorations. The results were in accordance with the results of the present study. In the present study, the ceramic veneered margin group showed similar microleakage values to the non-veneered zirconia group. Different from the mentioned studies, in the present study, the effect of ceramic veneering on zirconia frameworks were evaluated by measuring the marginal microleakage values after cementation on natural human teeth. Single type of a veneering ceramic and a zirconia material was used; therefore, the methodology differences might contribute to the different conclusions.

In the present study, the layering technique was used as a veneering method. Both the layering technique and the press technique can be utilized to veneer zirconia frameworks (1,6). The layering technique achieves superior esthetic results far more often than the pressing technique by means of individual contouring of the ceramic veneer. This veneering technique, which comprises a firing procedure at a high temperature (750-900 °C) followed by a cooling process, is often performed two to five times of firing cycle (29). Balkaya et al. (11) investigated the effect of the firing cycles on the marginal fit of ceramic crowns, and reported that porcelain firing cycle altered the marginal adaptation of the ceramic crowns. Numerous firing processes could bring about a distortion and a decrease in the marginal adaptation of the framework (27). However, in the present study, ceramic veneering was completed after two firings. Therefore, the increased microleakage values due to distortion and poor adaptation created by repeated firings were tried to be eliminated. Furthermore, distinctions in the ceramic materials’ structures and different manufacturing methods may create different results (30).

In the literature, shoulder, chamfer, and mini-chamfer finish lines of CAD/CAM-fabricated crowns have been investigated (8,30-32). Comlekoglu et al. (8) recommended rounded shoulder and chamfer preparation for the finish line designs of zirconia-supported restorations as they showed better marginal adaptation than feather-edged finish line. Komine et al. (32) also evaluated the marginal adaptation of three types of finish lines as shoulder, rounded shoulder, and chamfer. The three groups had no significant differences, and marginal adaptation values were within clinically acceptable limits. Al-Zubaidi and Al-Shamma (30) evaluated the effect of 90° shoulder and deep chamfer finish lines on the marginal adaptation of zirconia crowns and reported that the deep chamfer finish line was better than the shoulder, especially for zirconia crowns. Pan et al. (33) concluded that chamfer-type finish line with a 0.4-0.6 mm or shoulder-type finish line with a 0.5 mm thickness showed lower peak stress values than feather-edged finish lines in zirconia restorations. In the present study, 0.6 mm thickness chamfer finish line was prepared for the zirconia support.

Marginal discrepancies can be detected using various measurement techniques, such as a direct view of the crown on a die, the impression replica technique, observation with scanning electron microscopy (SEM), light microscopy, or X-ray microtomography (12,34). In the present study, the effects of different finish-line materials on the marginal microleakage of veneered zirconia crowns were evaluated using a stereo microscope. Groten et al. (35) investigated both SEM and light microscopy while evaluating marginal adaptation and concluded that there was no significant difference in validity between these imaging techniques. On the other hand, obtaining a small number of cross-sections from a specimen is a limitation of the evaluation with a microscope (12).

Study Limitations

In the present study, one type of resin cement was used while luting the crowns, different cementing procedures and cements might result in different marginal leakage values. Also, one type of zirconia and veneering ceramic was used, further studies were required to measure the marginal microleakage values of different zirconia and compatible veneering ceramic combinations. Various techniques may be combined while evaluating the marginal microleakage values to eliminate the technique-related limitations.


Conclusion

Within the limitations of this in vitro study, the non-veneered zirconia margin group showed similar microleakage values to the ceramic veneered margin group. It could be concluded that lithium-disilicate glass-ceramic veneering for zirconia-supported restorations did not enhance the marginal seal capability.

Ethics

Ethics Committee Approval: This study was approved by the İstanbul Okan University Clinical Research Ethics Committee (approval number: 56665618-204.01.07, date: 22.07.2020).

Informed Consent: Informed consent is not required.

Authorship Contributions

Concept: M.E.Ç., Design: M.E.Ç., Data Collection or Processing: G.P., B.E., Analysis or Interpretation: G.P., B.E., Literature Search: G.P., B.E., Writing: G.P., B.E.

Conflict of Interest: No conflict of interest was declared by the authors.

Financial Disclosure: The authors declared that this study received no financial support.


Images

  1. Alqutaibi AY, Ghulam O, Krsoum M, Binmahmoud S, Taher H, Elmalky W, et al. Revolution of Current Dental Zirconia: A Comprehensive Review. Molecules 2022;27:1699.
  2. Borba M, Cesar PF, Griggs JA, Della Bona Á. Adaptation of all-ceramic fixed partial dentures. Dent Mater 2011;27:1119-26.
  3. Komine F, Blatz MB, Matsumura H. Current status of zirconia-based fixed restorations. J Oral Sci 2010;52:531-9.
  4. Karataşli O, Kursoğlu P, Capa N, Kazazoğlu E. Comparison of the marginal fit of different coping materials and designs produced by computer aided manufacturing systems. Dent Mater J 2011;30:97-102.
  5. Beuer F, Stimmelmayr M, Gueth JF, Edelhoff D, Naumann M. In vitro performance of full-contour zirconia single crowns. Dent Mater  2012;28:449-56.
  6. Tang X, Nakamura T, Usami H, Wakabayashi K, Yatani H. Effects of multiple firings on the mechanical properties and microstructure of veneering ceramics for zirconia frameworks. J Dent 2012;40:372-80.
  7. Miyazaki T, Nakamura T, Matsumura H, Ban S, Kobayashi T. Current status of zirconia restoration. J Prosthodont Res 2013;57:236-61.
  8. Comlekoglu M, Dundar M, Ozcan M, Gungor M, Gokce B, Artunc C. Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns. Oper Dent 2009;34:586-92.
  9. Hasanzade M, Shirani M, Afrashtehfar KI, Naseri P, Alikhasi M. In Vivo and In Vitro Comparison of Internal and Marginal Fit of Digital and Conventional Impressions for Full-Coverage Fixed Restorations: A Systematic Review and Meta-analysis. J Evid Based Dent Pract  2019;19:236-54.
  10. Tao J, Yoda M, Kimura K, Okuno O. Fit of metal ceramic crowns cast in Au-1.6 wt% Ti alloy for different abutment finish line curvature. Dent Mater 2006;22:397-404.
  11. Balkaya MC, Cinar A, Pamuk S. Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems. J Prosthet Dent  2005;93:346-55.
  12. Contrepois M, Soenen A, Bartala M, Laviole O. Marginal adaptation of ceramic crowns: a systematic review. J Prosthet Dent 2013;110:447-54.
  13. Srimaneepong V, Heboyan A, Zafar MS, Khurshid Z, Marya A, Fernandes GVO, et al. Fixed Prosthetic Restorations and Periodontal Health: A Narrative Review. J Funct Biomater 2022;13:15.
  14. Freire Y, Gonzalo E, Lopez-Suarez C, Suarez MJ. The Marginal Fit of CAD/CAM Monolithic Ceramic and Metal-Ceramic Crowns. J Prosthodont 2019;28:299-304.
  15. Chang B, Goldstein R, Lin CP, Byreddy S, Lawson NC. Microleakage around zirconia crown margins after ultrasonic scaling with self-adhesive resin or resin modified glass ionomer cement. J Esthet Restor Dent 2018;30:73-80.
  16. Yüksel E, Zaimoğlu A. Influence of marginal fit and cement types on microleakage of all-ceramic crown systems. Braz Oral Res  2011;25:261-6.
  17. Rossetti PH, do Valle AL, de Carvalho RM, De Goes MF, Pegoraro LF. Correlation between margin fit and microleakage in complete crowns cemented with three luting agents. J Appl Oral Sci 2008;16:64-9.
  18. Grenade C, Mainjot A, Vanheusden A. Fit of single tooth zirconia copings: comparison between various manufacturing processes. J Prosthet Dent 2011;105:249-55.
  19. Quintas AF, Oliveira F, Bottino MA. Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents: an in vitro evaluation. J Prosthet Dent 2004;92:250-7.
  20. Habib SR, Al Ajmi MG, Al Dhafyan M, Jomah A, Abualsaud H, Almashali M. Effect of Margin Designs on the Marginal Adaptation of Zirconia Copings. Acta Stomatol Croat 2017;51:179-87.
  21. Della Bona A, Mecholsky JJ Jr, Barrett AA, Griggs JA. Characterization of glass-infiltrated alumina-based ceramics. Dent Mater 2008;24:1568-74.
  22. Kern M, Wegner SM. Bonding to zirconia ceramic: adhesion methods and their durability. Dent Mater 1998;14:64-71.
  23. Eliasson ST, Dahl JE. Effect of thermal cycling on temperature changes and bond strength in different test specimens. Biomater Investig Dent 2020;7:16-24.
  24. Att W, Komine F, Gerds T, Strub JR. Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses. J Prosthet Dent 2009;101:239-47.
  25. Dittmer MP, Borchers L, Stiesch M, Kohorst P. Stresses and distortions within zirconia-fixed dental prostheses due to the veneering process. Acta Biomater 2009;5:3231-9.
  26. Kohorst P, Brinkmann H, Dittmer MP, Borchers L, Stiesch M. Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses. J Oral Rehabil 2010;37:283-91.
  27. Pak HS, Han JS, Lee JB, Kim SH, Yang JH. Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns. J Adv Prosthodont 2010;2:33-8.
  28. Vigolo P, Fonzi F. An in vitro evaluation of fit of zirconium-oxide-based ceramic four-unit fixed partial dentures, generated with three different CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles. J Prosthodont 2008;17:621-6.
  29. Oilo M, Gjerdet NR, Tvinnereim HM. The firing procedure influences properties of a zirconia core ceramic. Dent Mater  2008;24:471-5.
  30. Al-Zubaidi ZAK, Al-Shamma AMW. The Effect of Different Finishing Lines on the Marginal Fitness of Full Contour Zirconia and Glass Ceramic CAD/CAM Crowns (An in-vitro study). J Dent Mater Tech 2015;4:127-36.
  31. Bindl A, Mörmann WH. Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations. J Oral Rehabil  2005;32:441-7.
  32. Komine F, Iwai T, Kobayashi K, Matsumura H. Marginal and internal adaptation of zirconium dioxide ceramic copings and crowns with different finish line designs. Dent Mater J 2007;26:659-64.
  33. Pan CY, Lan TH, Liu PH, Fu WR. Comparison of Different Cervical Finish Lines of All-Ceramic Crowns on Primary Molars in Finite Element Analysis. Materials (Basel) 2020;13:1094.
  34. Nawafleh NA, Mack F, Evans J, Mackay J, Hatamleh MM. Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: a literature review. J Prosthodont 2013;22:419-28.
  35. Groten M, Girthofer S, Pröbster L. Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light and scanning electron microscopic analysis in vitro. J Oral Rehabil 1997;24:871-81.